Emergency lighting is a critical part of building safety because it provides illumination when the normal power supply fails. During a blackout, fire, electrical fault or other emergency, occupants need to be able to identify exits, follow escape routes, avoid hazards & reach a safe location.
Correct placement is just as important as the type of fitting installed. A building may contain emergency lights, but if they do not adequately illuminate exits, stairs, changes in level or key safety equipment, evacuation can still become difficult.
For building owners, facility managers, strata managers & commercial operators, understanding where emergency lights are generally required helps support safer premises & compliance planning.
Businesses reviewing Emergency Lighting Perth requirements should consider the complete path an occupant may need to follow from an occupied area to a final exit, rather than treating emergency lights as isolated fittings.
Emergency Lighting at Exits
Exits are one of the most important locations for emergency illumination. Occupants must be able to recognise & reach an exit when normal lighting is unavailable.
Emergency lighting is commonly required around designated exits & along the routes leading to them. Exit signs & emergency luminaires serve different functions: exit signs identify the direction or location of an exit, while emergency lights provide enough illumination for occupants to move safely.
Lighting should be positioned so doors, thresholds & the immediate area around an exit remain visible during a power failure. Final exits should also allow occupants to move safely from the building towards an appropriate external area.
Changes in Floor Level
Unexpected changes in floor level can become significant trip & fall hazards when a building loses normal lighting.
Emergency illumination should therefore address locations such as steps, ramps, raised sections, changes in floor height & other level transitions along required paths of travel.
The objective is to make the change clearly visible so occupants can adjust their movement before reaching it. This is particularly important in unfamiliar buildings where visitors may not know that a step, ramp or level change is ahead.
Intersections & Changes of Direction
Escape routes are not always straight. Corridors may intersect, divide or change direction before reaching an exit.
Emergency lights should provide suitable visibility at these decision points. Corridor intersections, junctions & changes of direction need to remain understandable so occupants can follow the intended evacuation route without confusion.
Exit signage may also be required to indicate the correct direction of travel. Emergency lighting supports these signs by illuminating the surrounding path & potential obstacles.
Staircases & Stairwells
Staircases present a higher risk during an evacuation because occupants must negotiate individual steps, landings, handrails & changes in direction.
Emergency lighting should provide suitable illumination throughout required stairs & stairwells, including landings & areas where people enter or leave the stairway. Lighting needs to help occupants distinguish the stair profile & move without relying on the normal building lighting.
Multi-storey offices, apartment buildings, hotels, shopping centres & other larger premises may depend heavily on stairways during an emergency because lifts may not be available for normal evacuation.
Fire Equipment Locations
Emergency conditions may require building occupants, wardens or emergency personnel to locate fire safety equipment quickly.
Where required, emergency illumination should support visibility around important fire equipment & safety points. Depending on the building & its fire safety design, these areas may include extinguishers, hose reels, hydrant-related equipment, fire alarm equipment or other emergency facilities.
A broader Fire Safety Perth assessment should consider whether essential equipment remains identifiable when the normal lighting system fails.
Escape Routes & Corridors
Emergency lighting needs to support the full path of travel to an exit. Installing a light near the exit door alone may not provide sufficient visibility along a long corridor or complex evacuation route.
Escape paths can include corridors, hallways, passageways, lobbies & other circulation areas used to reach an exit. Lighting should enable occupants to identify the route, recognise obstacles & continue moving towards safety.
Long corridors, large open areas & routes with multiple turns may require several emergency luminaires to achieve appropriate coverage.

Plant Rooms & Service Areas
Plant rooms can contain electrical equipment, mechanical systems, pipework, machinery, switchgear & other hazards. If normal lighting fails while workers are inside, leaving the space safely may be difficult.
Emergency lighting may be required in plant rooms, switchrooms & other service areas depending on the building classification, room function, layout & applicable requirements.
Particular attention should be given to access points, exit paths, stairs, equipment hazards & areas where personnel may need to operate essential controls.
These spaces should be assessed as part of the building’s overall emergency lighting design rather than treated as low-priority areas simply because they are not normally occupied by the public.
Toilets & Amenities
Some toilets & sanitary facilities may require emergency lighting depending on their size, configuration, building classification & applicable building requirements.
Large or complex toilet areas can be difficult to navigate during a complete lighting failure, particularly where cubicles, partitions & internal corridors obstruct a direct view of the exit.
Emergency illumination can help occupants leave the facility & reconnect with the main evacuation path. Accessible sanitary facilities & other amenities should also be considered within the overall building safety assessment.
Open Areas & Large Rooms
Large rooms & open-plan spaces also require consideration because occupants may be some distance from a corridor or clearly marked exit.
Offices, retail floors, warehouses, function rooms & other substantial spaces may need emergency luminaires positioned to help people identify the direction of travel & reach an escape route.
The number & position of fittings should be based on the building design, required illumination, mounting height, luminaire performance & applicable compliance requirements rather than a simple fixed spacing rule.
Why Emergency Light Placement Must Be Planned
Emergency lighting design is not simply a matter of installing fittings at regular intervals. Placement needs to reflect how people will actually evacuate the building.
A proper assessment should consider:
- Exits & final exits
- Required paths of travel
- Stairways & landings
- Corridor intersections & direction changes
- Changes in floor level
- Fire safety equipment
- Plant & service rooms
- Toilets & amenities
- Large open areas
- Obstacles or hazards affecting evacuation
The applicable National Construction Code provisions & relevant Australian Standards should also be considered when emergency lighting systems are designed, installed, tested or upgraded. Requirements can vary according to building classification, use, size & configuration.
Emergency Lighting Is Part of a Wider Safety System
Emergency lights work alongside exit signs, fire detection systems, alarms, fire extinguishers, hose reels & other building safety measures. Each element has a different role, but they need to support the same objective: helping occupants respond & evacuate safely.
For this reason, Fire Safety Perth planning should consider emergency illumination as part of the building’s complete fire & evacuation strategy rather than as a stand-alone electrical installation.
Reviewing Existing Emergency Lighting
Building layouts change over time. Partitions may be added, offices reconfigured, warehouses rearranged or escape routes altered. These changes can affect whether existing emergency lights still provide appropriate coverage.
Older fittings can also experience battery deterioration, reduced light output or component failure. Regular inspection & testing are therefore important for identifying faults before emergency operation is needed.
Property owners & facility managers reviewing Emergency Lighting Perth systems should check whether current fittings suit the building’s present layout, not simply whether emergency lights are installed.
Correct Placement Supports Safer Evacuation
Emergency lights should be positioned wherever occupants need reliable visibility to evacuate safely during failure of the normal lighting system. Key areas include exits, escape routes, staircases, corridor intersections, changes in floor level, fire equipment locations, plant rooms, toilets & larger occupied spaces.
Because requirements depend on the building’s classification, layout, use & evacuation design, emergency lighting should be assessed against applicable building, electrical & safety requirements. Correct placement, suitable illumination & ongoing testing all contribute to a safer & more reliable emergency lighting system.